_GM (KD9) - Auxiliary Generator Provision
Build Options
- Single 125 Amp Generator (KG7)
- Single 145 Amp Generator (KG3)
- Single 160 Amp Generator (KW1)
- Single 220 Amp Generator (KW5)
- Dual 145 Amp Generators (KD9)
Generator Control
The engine control module (ECM) controls the generator through the generator turn on signal. It monitors the generator performance though the generator field duty cycle signal circuit. The signal is a 5 volt pulse width modulation (PWM) signal of 128 Hz with a duty cycle of 0-100 percent. Normal duty cycle is between 5-95 percent. Between 0-5 percent and 95-100 percent are for diagnostic purposes. The following table shows the commanded duty cycle and output voltage of the generator: The generator provides a feedback signal of the generator voltage output through the generator field duty cycle signal circuit to the ECM. This information is sent to the body control module (BCM). The signal is a 5 volt PWM signal of 128 Hz with a duty cycle of 0-100 percent. Normal duty cycle is between 5-99 percent. Between 0-5 percent and 100 percent are for diagnostic purposes.